Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Filter by Categories
Book Review
Case Report
Case Series
Clinical Article
Clinical Innovation
Clinical Pearl
Clinical Pearls
Clinical Showcase
Clinical Technique
Critical Review
Editorial
Expert Corner
Experts Corner
Featured Case Report
Guest Editorial
Letter to Editor
Media and News
Original Article
Original Research
Research Gallery
Review Article
Special Article
Special Feature
Systematic Review
The Experts Corner
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Filter by Categories
Book Review
Case Report
Case Series
Clinical Article
Clinical Innovation
Clinical Pearl
Clinical Pearls
Clinical Showcase
Clinical Technique
Critical Review
Editorial
Expert Corner
Experts Corner
Featured Case Report
Guest Editorial
Letter to Editor
Media and News
Original Article
Original Research
Research Gallery
Review Article
Special Article
Special Feature
Systematic Review
The Experts Corner
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Filter by Categories
Book Review
Case Report
Case Series
Clinical Article
Clinical Innovation
Clinical Pearl
Clinical Pearls
Clinical Showcase
Clinical Technique
Critical Review
Editorial
Expert Corner
Experts Corner
Featured Case Report
Guest Editorial
Letter to Editor
Media and News
Original Article
Original Research
Research Gallery
Review Article
Special Article
Special Feature
Systematic Review
The Experts Corner
View/Download PDF

Translate this page into:

Clinical Pearl
6 (
5
); 271-272
doi:
10.4103/2321-1407.190749

Versatile Twin-block design for noncompliance class II correction

Department of Orthodontics, Nair Dental College and Hospital, Mumbai, India
Department of Orthodontics, Government Dental College and Hospital, Nagpur, India
Department of Orthodontics, CSMSS Dental College and Hospital, Aurangabad, Maharashtra, India
Address for Correspondence: Dr. Umal Hiralal Doshi, UPHAR, 68, Builders Society, Near Nandanvan colony, Aurangabad, Maharashtra, India. E-mail: umal_16@rediffmail.com
Licence
This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
Disclaimer:
This article was originally published by Wolters Kluwer and was migrated to Scientific Scholar after the change of Publisher.

How to cite this article: Chandorikar H, Bhad WA, Doshi UH, Chavan S. Versatile Twin-block design for noncompliance class II correction. APOS Trends Orthod 2016;6:271-2.

Abstract

Compliance for removable Twin-block appliance wear is one of the most common problems for successful functional correction. This article describes a simple but versatile semi-fixed Twin-block design that ensures full-time wear of the appliance with provision of possible modifications in different clinical situations.

Keywords

Class II
noncompliance
Twin Block

INTRODUCTION

Twin-block appliance developed by Clark[1] is one of the most commonly used functional appliances in contemporary orthodontic practice. For success with this removable functional appliance, much patient cooperation is required. In noncompliant patients fixing the Twin-block for some period has been suggested.[1] But, since controlled trimming is not possible, the appliance has to be removed and continued as a removable appliance. In addition, other fixed Twin-block designs require complicated laboratory procedures.[2]

To overcome these problems, the authors have developed a simple and effective semi-fixed Twin-block appliance.

STEPS IN FABRICATION OF SEMI-FIXED TWIN BLOCK

  1. Both maxillary permanent molars are banded. Lingual sheaths are welded vertically on buccal and lingual aspects with their long axis parallel to each other [Figure 1a]

  2. Pick-up impression of the maxillary arch is made, and the molar bands are transferred in the impression. Working cast is prepared

  3. Bite registration is done in a conventional manner and working casts along with wax bite are mounted on hinge articulator

  4. A 20-gauge hard stainless steel wire is used to make double backs such that it fits the lingual sheath. The two ends of the double back should be opposite to each other [Figure 1b]. Such double backs are made for each sheath. The lengths of the double backs should be such that free ends are close to the occlusal surface

  5. The maxillary block is prepared as per standard Twin-block design with inclined planes at about 70° to the occlusal plane. The free ends of the double backs placed in the vertical sheaths are incorporated into the acrylic blocks [Figure 1c]

  6. Lower block is prepared in a conventional manner either with delta clasp or simple acrylic splint carrying the blocks can be prepared and directly cemented to mandibular anterior teeth if required [Figure 1d]. A thick gauge wire can be added to reinforce this segment

  7. Maxillary molar bands with blocks and lower blocks are cemented [Figure 2a and b]

  8. When trimming is required maxillary acrylic blocks with double backs are removed from bands and trimmed

  9. After completion of active phase same maxillary bands with lingual sheaths are used for making fixed inclined plane [Figure 2c]

  10. Retention phase is continued till occlusal settling is complete [Figure 2d].

Figure 1
(a) Molar bands with vertical lingual sheath (b) double back (c) maxillary block (d) mandibular block
Figure 2
(a) Pretreatment (b) semi-fixed Twin-block (c) fixed inclined plane (d) posttreatment

ADVANTAGES

  1. Easy to fabricate with no special attachments or laboratory procedures

  2. Less patient dependency and whenever required, ease of placing anterior brackets reduces treatment time significantly

  3. Better patient acceptance, since palatal mucosa is completely acrylic free

  4. Maxillary blocks can be easily removed and trimmed for selective eruption of mandibular molars in class II deep bite cases. This is not possible in other designs of fixed Twin blocks

  5. In retention phase, appliance can be easily converted into fixed inclined plane

  6. Similar design in class III cases for reverse Twin block can also be made

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

References

  1. . Twin Block Functional Therapy – Applications in Dentofacial Orthopaedics. London: Mosby-Wolfe; .
  2. , , , , . A preliminary report of a new design of cast metal fixed twin-block appliance. J Orthod. 2007;34:213-9.
    [Google Scholar]
Show Sections